7 Parameters348
Continued
7.3 Control Parameters
7.3 Control Parameters
Control Parameters
1 – Settings
■ Deactivate printer output:Using the PRINTA command in an NC
program, you can output data on a printer (see also control parameter
40, ...).
■ 0: Output deactivated
■ 1: Output activated.
■ Metric / Inch: Definition of the system of measurement
■ 0: Metric system
■ 1: Inch system
■ Display format of position display (actual value display)
■ 0: Format 4.3 (4 integer positions, 3 decimal places)
■ 1: Format 3.4 (3 integer positions, 4 decimal places)
■ In DIN PLUS programs, the unit of measure is defined in the
program head and is independent of the setting made here.
■ Restart the CNC PILOT after having changed the unit of
measure.
8 – Load monitoring settings
Evaluation: Load monitoring
■ Factor for torque limit value 1
■ Factor for torque limit value 2
■ Factor for work limit value
The CNC PILOT calculates as follows:
Limit value = reference value * factor for limit value
■ Minimum torque [% of rated torque]:
Reference values that remain below this value are raised to this
minimum torque value. This prevents that limit values are exceeded as
a result of minor torque differences.
■ Maximum file size [KB]:
If the data during measured value registration exceed the maximum
file size, the ”oldest” values are overwritten.
Approximate value: For one component per minute of program run time
approximately 12 KB.
10 – Post-process measuring
Evaluation: Post-process measuring
■ Activate measuring function
■ 0: Postprocess measuring function off
■ 1: Postprocess measuring function on – the CNC PILOT is ready to
receive data
Commentaires sur ces manuels