386 10 Programming: Q Parameters
10.7 Checking and Changing Q Parameters
10.7 Checking and Changing Q
Parameters
Procedure
You can check and edit Q parameters when writing, testing and
running programs in the Programming and Editing, Test Run, Program
Run Full Sequence, and Program Run Single Block modes.
U
UU
U If you are in a program run, interrupt it if required (for example by
pressing the machine STOP button and the INTERNAL STOP soft
key). If you are doing a test run, interrupt it.
U
UU
U To call Q parameter functions: Press the Q key or the
Q INFO soft key in the Programming and Editing
mode of operation.
U
UU
U The TNC lists all parameters and their current values.
With the arrow keys or the soft keys, go pagewise to
the desired parameters.
U
UU
U If you would like to change the value, enter a new
value and confirm with the ENT key.
U
UU
U To leave the value unchanged, press the PRESENT
VALUE soft key or end the dialog with the END key.
The parameters (parameter numbers > 100) used by the
TNC are provided with comments.