Vue de la page 495
468 12 MOD Functions
12.16 External Access
12.16 External Access
Function
The soft key SERVICE can be used to grant or restrict access through
the LSV-2 interface.
With an entry in the configuration file TNC.SYS you can protect a
directory and its subdirectories with a password. The password is
requested when data from this directory is accessed from the LSV-2
interface. Enter the path and password for external access in the
configuration file TNC.SYS.
Example of TNC.SYS
Permitting/Restricting external access
U
UU
U Select any machine mode of operation.
U
UU
U To select the MOD function, press the MOD key.
U
UU
U Permit a connection to the TNC: Set the EXTERNAL
ACCESS soft key to ON. The TNC will then permit
data access through the LSV-2 interface. The
password is requested when a directory that was
entered in the configuration file TNC.SYS is accessed.
U
UU
U Block connections to the TNC: Set the EXTERNAL
ACCESS soft key to OFF. The TNC will then block
access through the LSV-2 interface.
The machine tool builder can configure teleservice
settings with the LSV-2 interface. The machine tool
manual provides further information.
The TNC.SYS file must be stored in the root directory
TNC:\.
If you only supply one entry for the password, then the
entire drive TNC:\ is protected.
You should use the updated versions of the HEIDENHAIN
software TNCremo or TNCremoNT to transfer the data.
Entries in TNC.SYS Meaning
REMOTE.TNCPASSWORD= Password for LSV-2 access
REMOTE.TNCPRIVATEPATH= Path to be protected
REMOTE.TNCPASSWORD=KR1402
REMOTE.TNCPRIVATEPATH=TNC:\RK