74 1 Operation
1.1 Operation
Plane probing technique
A plane can be measured by probing three seed points for the data
cloud. The IK 5000 fitting algorithm uses these three points as the first
three corners of the plane.
It is important to probe the three seed points on the corner surfaces
of the actual plane if the Add Probe Points function is used to add
more points to the data cloud of the plane measurement.
6HHGSRLQW
6HHGSRLQW
6HHGSRLQW
3UREHGSODQH
$FWXDOSODQHVXUIDFH
Correct probing technique
6HHGSRLQW
6HHGSRLQW
6HHGSRLQW
3UREHGSODQH
$FWXDOSODQHVXUIDFH
$GGHGSUREHSRLQWV